Section 601 General
601.1 Scope: This chapter specifies the construction type for the building
Section 602 Construction Classification
602.1 General:
- Buildings and structures to be built, altered, or extended in height or area must be categorized into one of five construction types (Sections 602.2 to 602.5).
- Building elements must have a fire-resistance rating as specified in Table 601.
Exterior walls require a fire-resistance rating as detailed in Table 602. - If Table 601 mandates a fire-resistance rating, building elements must adhere to Section 703.2.
- Protection for openings, ducts, and air transfer openings in building elements is not mandatory unless specified by other code provisions.
602.2 Type I and II
- Types I and II of construction refer to construction types where building elements in Table 601 are made of non-combustible materials.
602.3 Type III
- Exterior walls are made of noncombustible materials and interior building elements can be made of any material allowed by the code.
602.4 Type IV
- (Heavy timber construction) Exterior walls of noncombustible materials and the interior building elements made of solid or laminated wood without hidden spaces.
602.5 Type V
- Type of construction in which the structural elements, exterior walls and interior walls are of any materials permitted by this code.
Section 603 Combustible Materials in Type I and II Construction
603.1 Allowable materials
- Combustible materials in Type I or II is allowed in the following cases:
- Fire-retardant-treated wood is permitted in:
- Nonbearing partitions with a fire-resistance rating of 2 hours or less.
- Nonbearing exterior walls where fire-resistance-rated construction is not required.
- Roof construction, including girders, trusses, framing, and decking.
- Ducts
- Nonmetallic ducts are allowed if installed according to the Saudi Mechanical Code.
- Piping
- Combustible piping materials can be used if installed following the Saudi Mechanical Code and Saudi Plumbing Code.
- Electrical
- Electrical wiring with combustible insulation, tubing, raceways, and related components are permitted if installed according to this code’s limitations.
- Fire-retardant-treated wood is permitted in: